TFC Jet Pump replaces ESP in Woodbine formation well and substantially reduces workover cost while continually chemically treating wellbore.
A Madison County, Texas, well in the Woodbine formation being produced with an ESP was facing high workover cost due to produced solids content and scaling issues. The well was unable to be chemically treated with the ESP and mechanical failures were common.
To eliminate the need for workovers, handle solids and chemically treat the wellbore for scale and corrosion.
After being shut in for several months, a TFC jet pump was installed in the well in August of 2011. A 200 HP
triplex pump driven by a Cummins natural gas engine was selected for the surface equipment. In a matter of two days the installation process was complete and the well was producing.
Tech-Flo’s permanent unit with Cummins natural gas engine.